1. Pressing the tab of the LC connector, pull out the LC connector from the transceiver module.
Put on the dust cap for the LC connector.
2. Pivot the clasp of the transceiver module down to the horizontal position.
3. Hold the clasp to pull the transceiver module out of the socket.
4. Put the dust plug on the removed module, and put the removed module into its original shipping
materials.
5. Install a new transceiver module.
For the installation procedures, see "Connecting a fiber port."
Figure 53 Replacing a transceiver module
Replacing a power module
The F5000-A5 firewall supports AC and DC power modules. The following describes how to remove an
AC power module.
To replace a power module:
1. Face the front panel of the firewall.
2. Loosen the captive screws on the power module with a Phillips screwdriver until all pressure is
released.
3. Supporting the bottom of the power module with one hand, and holding the handle of the power
module with the other hand, gently pull the power module out along the slide rails.
Place the removed power module in an antistatic bag or on the antistatic workbench.