H3c-technologies H3C SecPath F5000-A5 Firewall User Manual Page 108

  • Download
  • Add to my manuals
  • Print
  • Page
    / 121
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 107
98
interface-type represents the type of the interface such as GigabitEthernet.
X represents the number of the slot where the interface module resides, in the range of 1 to 4.
Y represents the sequence number of the interface on the interface module, depending on the
interface module model.
Note the following:
Interfaces on the same interface module have the same slot number X.
For each type of interfaces, the sequence number Y starts from 0 and increases according to the
sequence on the interface module (from bottom to up or from left to right).
The management Ethernet port is permanently numbered as M-GigabitEthernet0/0.
The HA port is permanently Inner-Ethernet0/1.
Examples
If an interface module is installed in Slot 1, interfaces on the interface module are numbered as follows:
GigabitEthernet 1/0 and GigabitEthernet 1/1.
Or:
Ten-GigabitEthernet 1/0 and Ten-GigabitEthernet 1/1.
Page view 107
1 2 ... 103 104 105 106 107 108 109 110 111 112 113 ... 120 121