H3c-technologies H3C SecBlade IPS Cards User Manual Page 44

  • Download
  • Add to my manuals
  • Print
  • Page
    / 85
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 43
37
To do… Use the command…
Remarks
Set the SNMP version
snmp-agent sys-info
{ contact sys-contact |
location sys-location |
version { all | { v1 | v2c
| v3 }* } }
Required
Currently, the SecBlade IPS card only supports
SNMPv3.
By default, SNMPv3 applies.
Configure a new SNMP group
and configure its access right
For SNMP v3:
snmp-agent group v3
group-name
[ authentication |
privacy ] [ read-view
read-view ] [ write-view
write-view ]
[ notify-view
notify-view ] [ acl
acl-number ]
Required
By default, the SNMP group configured with
the snmp-agent group v3 command adopts
non-authentication and non-encryption.
Create or update a MIB view to
specify the MIB objects that the
NMS can access
snmp-agent mib-view
{ excluded | included }
view-name oid-tree
[ mask mask-value ]
Required
The default view is ViewDefault.
Add a user to the SNMP group
snmp-agent usm-user
v3 user-name
group-name [ [ cipher ]
authentication-mode
{ md5 | sha }
auth-password
[ privacy-mode { des56
| aes128 }
priv-password ] ] [ acl
acl-number ]
Required
If you execute this command for the same user
repeatedly, the last configuration takes effect.
Enable the ACFP server acfp server enable
Required
Disabled by default.
Enable the ACSEI server acsei server enable
Required
Disabled by default.
Page view 43